Vector® TrueVIEW™ Autofluorescence Quenching Kit with DAPI
Code produit : VEC.SP-8500
VEC.SP-8500The Vector TrueVIEW Autofluorescence Quenching Kit provides a novel way to diminish unwanted autofluorescence from non-lipofuscin sources and dramatically improve signal-to-noise ratio.
En cliquant sur le bouton "demande de devis", vous pouvez nous contacter pour plus d'informations.
Vector® TrueVIEW™ Autofluorescence Quenching Kit with DAPI
Product Description
Features:
- Removes unwanted autofluorescence in tissue sections due to aldehyde fixation, red blood cells, and structural elements such as collagen and elastin
- Improves overall signal-to-noise in most immunofluorescence assays
- Effective on problematic tissues such as kidney and spleen
- Easy-to-use, one-step method
- Compatible with a wide selection of fluorophores
- Compatible with standard epifluorescence and confocal laser microscopes
Kit Contents:
- Vector TrueVIEW Reagent A, 5 ml
- Vector TrueVIEW Reagent B, 5 ml
- Vector TrueVIEW Reagent C, 5 ml
- VECTASHIELD® Vibrance™ Antifade Mounting Medium with DAPI, 2 ml
One kit is sufficient to treat approximately 100 to 150 tissue sections.
More Information
Tissue autofluorescence often occurs with aldehyde fixation or from inherent native tissue components (collagen, elastin, and red blood cells). The extent and intensity of autofluorescence background frequently makes it difficult or impossible to distinguish specific signals in immunofluorescence applications.
Most methods for reduction of tissue autofluorescence act primarily on lipofuscin granules, and are not broadly effective against the most common sources of autofluorescence targeted by Vector TrueVIEW Quencher.
The Vector TrueVIEW Autofluorescence Quenching Kit provides a novel way to diminish unwanted autofluorescence from non-lipofuscin sources and dramatically improve signal-to-noise ratio. The quenching action of the kit reagents provides a clear, unambiguous, “true view” localization of the target antigen.
Current methods for reducing autofluorescence primarily include “home brew” concoctions such as sodium borohydride and other ink-based products. These methods are essentially ineffective against aldehyde induced autofluorescence. In contrast, Vector TrueVIEW reagent binds to hydrophilic compounds and effectively quenches endogenous autofluorescence.
Publications:
-
Boucher, J.M., Robich, M., Scott, S.S. et al (2018). Rab27a Regulates Human Perivascular Adipose Progenitor Cell Differentiation. Cardiovasc Drugs Ther., (https://doi.org/10.1007/s10557-018-6813-y)
-
Du, H. et al (2018). A novel mouse model of hemangiopericytoma due to loss of Tsc2. Human Mol. Gen., (https://doi.org/10.1093/hmg/ddy289)
-
Su Y, Hou Y, Wang Q, (2018). The enhanced replication of an S-intact PEDV during coinfection with an S1 NTD-del PEDV in piglets, Veterinary Microbiology, (https://doi.org/10.1016/j.vetmic.2018.11.025)
-
Yoon, J.H., Li, M., Basile, J.R., Lin, Y (2018). Computer-assisted analysis of immunohistological parameters in oral giant cell granulomas, Oral Diseases, (https://doi.org/10.1111/odi.13022)
Human tonsil (FFPE); Section stained for AE1/AE3 using fluorescein label (green). Treated with TrueVIEW and mounted with VECTASHIELD Vibrance Antifade Mounting Medium with DAPI (nuclei blue).
Easy To Apply
Following completion of the IF staining procedure:
Mode of ActionFollowing completion of the IF staining procedure: |
Signal to Noise Optimization
The primary antibody and detection reagents should be optimized (titered) in conjunction with Vector TrueVIEW Quenching Kit to achieve maximum signal to noise.
Optimization of Exposure
Increasing exposure times may be necessary to achieve optimal image acquisition for TrueVIEW Quencher treated slides.
Comparison Between Vector TrueVIEW Reagent and Other Autofluorescence Reducing AgentsWe compared the effectiveness of Vector TrueVIEW quenching action in parallel with other commercially available autofluorescence reducing products and "home brew" reagents, on serial sections of formalin-fixed, paraffin-embedded human pancreas visualized using a standard fluorescein (green) filter. No specific immunofluorescence staining was conducted. The images below highlight our results. All images were acquired under identical conditions (including microscope objective and exposure times). |
Customer Testimonials |
Vector® TrueVIEW™ Autofluorescence Quenching Kit with DAPI
Spécifications du produit
Packaging Unit
15 ml
Brand
Vector Laboratories
Category
Protein blocking
Vector® TrueVIEW™ Autofluorescence Quenching Kit with DAPI
Documents de produit