LMC-4200R, Laboratory Refrigerated Centrifuge
Code produit : BSN.BS-010212-AAA
BSN.BS-010212-AAALaboratory bench-top centrifuge with refrigeration LMC-4200R provides temperature control of biomaterial during centrifugation. Temperature control of the so-called cold-shelf is a gold standard for enzymologists and cell biologists because it e…
En cliquant sur le bouton "demande de devis", vous pouvez nous contacter pour plus d'informations.
LMC-4200R, Laboratory Refrigerated Centrifuge
Product Description
Laboratory bench-top centrifuge with refrigeration LMC-4200R provides temperature control of biomaterial during centrifugation. Temperature control of the so-called cold-shelf is a gold standard for enzymologists and cell biologists because it ensures conditions necessary for reproducibility of the sample preparation stage. Temperature control absence at this stage can cause unpredictable results.
LMC-4200R is a modern centrifuge designed for operation with microtest plates, gel cards and tubes from 10 to 50 ml.
Features:
- Soft start and run-down of the rotor;
- Efficient rate of chamber refrigeration: under 10 min;
- Maintenance of stable temperature during operation;
- User-friendly setting of centrifugation parameters (speed, temperature, time) and simultaneous display of both set and actual values;
- Safe operation is provided by a metal protection chamber and a case cover, automatic stop at imbalance (emergency shutdown, "IMBALANCE" displayed) and a lock keeping the lid closed while the centrifuge is running.
- Rotor selection;*
- Setting rotor speed in RPM or RCF;*
- Multiple acceleration (Slow, Normal, Fast) and deceleration (0, Slow, Normal, Fast) modes and possibility to switch off forced braking;*
- Low noise level;
- Wide choice of accessory rotors.
*NEW FUNCTION
LMC-4200R, Laboratory Refrigerated Centrifuge
Spécifications du produit
Packaging Unit
1 Unit
Brand
Biosan
Chamber diameter
335 mm
Digital time setting
1-90 min (increment 1 min)
Dimensions (W-D-H)
635x580x335 mm
Display
LCD, 2 lines
Input current/power consumption (230V)
990 W (4.3 A)
Nominal operating voltage
230 V, 50 Hz
Rotor imbalance diagnostics
automatic stop, IMBALANCE warning
Slowdown time, not more
30 s
Speed control range
100-4200 rpm (3160 x g) for centrifuge tubes 100-2000 rpm (560 x g) for microtiter plates
Speed setting resolution
100 rpm
Stable temperature maintenance range
25°C below ambient ... to +25°C
Temperature control range
-10°C ... +25°C
Temperature setting resolution
1°C
Weight
56 kg